Crosslinked power cable
XLPE insulated power cable with rated voltage of 110kV(Um = 126kV)
Model number:YJLW02-Z copper core cross-linked polyethylene insulated corrugated aluminum sheathed or welded corrugated aluminum sheathed PVC sheathed longitudinal water blocking power cable
Voltage level:64/110kV
Use case:110kV insulated power cable, suitable for power supply system, can be laid in the air, indoor, tunnel, cable trench and pipeline or soil; the drop of cable laying is not limited. (including flame retardant type and halogen-free low smoke type)
Usage characteristics:The long-term allowable working temperature of the cable conductor is 90°C, and the ambient temperature during laying is not lower than 0°C.
Section range:240-1600mm2
Number of cores:1 core
Power cables with extruded insulation for rated voltages from 6kV(Um = 7.2kV) to 35kV(Um = 40.5kV)
Model number:YJV32 copper conductor XLPE insulated fine steel wire armored PVC sheathed power cable
Voltage level:26/35kV
Use case:3.6 ~ 35kV XLPE insulated cables are suitable for underground power grids in urban residential buildings and outgoing lines of substations (stations) for energy supply, transmission and distribution. The drop of cable laying is not limited. (including flame retardant type and halogen-free low smoke type)
Usage characteristics:The long-term allowable working temperature of the cable conductor is 90°C, and the ambient temperature during laying is not lower than 0°C
Section range:25~630mm2
Number of cores:1 core, 3 core
Power cables with extruded insulation for rated voltages of 1kV(Um = 1.2 kV) and 3kV( Um = 3.6 kV)
Model number:YJV33 copper conductor XLPE insulated fine steel wire armored PE sheathed power cable
Voltage level:0.6/1kV
Use case:0.6/1kV and below PVC all-plastic power cables are suitable for lines with rated voltage (U0/U = 0.6/1kV) for power transmission and distribution. Can be laid in the air, soil or cable trench, cable laying drop is not limited. (including flame retardant type, fire-resistant type and halogen-free low smoke type)
Usage characteristics:The long-term allowable working temperature of the cable conductor is 90°C, and the ambient temperature during laying is not lower than 0°C
Section range:25~630mm2
Number of cores:1 core, 3 core
Rated voltage 8.7/15kV shield machine cable EPDM rubber insulated neoprene rubber sheathed high voltage rubber sheathed flexible cable
Model number:UGEFP/UGEFHP EPDM rubber insulated neoprene rubber sheathed high voltage rubber sheathed flexible cable
Voltage level:3.6/6 6/6 6/10 8.7/10 8.7/15
Use case:Heavy equipment for open pit and underground tunneling
Usage characteristics:The maximum rated temperature of the cable conductor is 90°C. The maximum temperature of the cable conductor during short circuit (the maximum duration does not exceed 5 seconds) does not exceed 250°C. The minimum allowable ambient temperature of the cable: UGEFP type:-15°C:UGEFHP type:-33°C. The minimum allowable bending radius of the cable is 6D when it is used for fixing equipment; 10D when it is connected in a freely movable manner; 12D when it is retreated with the cable reel; 15D when it is used with the steering guide wheel (where D is the cable diameter).
1kV overhead insulated cable
Model number:JKLYJ Rated Voltage 1kV Aluminum Core XLPE Insulated Overhead Cable
Voltage level:1kV
Use case:It is suitable for transmission and distribution of overhead fixed laying power lines, lead-in lines, etc.
Usage characteristics:The long-term allowable working temperature of the cable conductor is 90°C, and the ambient temperature during laying is not lower than -20°C.
Section range:10-400mm2
Number of cores:1 core, 2 core, 4 core, 3 k core
Control cable
Model number:KVVRP2 PVC insulated PVC sheathed copper tape shielded flexible control cable
Voltage level:450/ 750V
Use case:Suitable for AC rated voltage 500V or DC voltage 1000V and below in the electrical distribution device wiring. Such as control circuit, monitoring circuit, protection line, etc., occasions. (including flame retardant type, fire resistant type and halogen free low smoke type).
Usage characteristics:The long-term allowable working temperature of the cable conductor is 70°C, and the ambient temperature during laying is not lower than 0°C
Section range:0.5~ 10mm2
Number of cores:2-61 core